Home> goxianzhan
Common Rail DLLA150P2207 Injector Nozzle Encyclopedia

1. DLLA150P2207 Injector Nozzle Technical Support   1.1. DLLA150P2207 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA150P2207 Injector Nozzle Encyclopedia

Common Rail DLLA150P2153 Injector Nozzle Encyclopedia

1. DLLA150P2153 Injector Nozzle Technical Support   1.1.  DLLA150P2153 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA150P2153 Injector Nozzle Encyclopedia

Common Rail DlLA150P2156 Injector Nozzle Encyclopedia

1. DlLA150P2156 Injector Nozzle Technical Support   1.1.  DlLA150P2156 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DlLA150P2156 Injector Nozzle Encyclopedia

Common Rail DLLA150P2125 Injector Nozzle Encyclopedia

1. DLLA150P2125 Injector Nozzle Technical Support   1.1.  DLLA150P2125 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA150P2125 Injector Nozzle Encyclopedia

Common Rail DLLA150P1695 Injector Nozzle Encyclopedia

1. DLLA150P1695 Injector Nozzle Technical Support   1.1.  DLLA150P1695 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA150P1695 Injector Nozzle Encyclopedia

Common Rail DLLA150P1606 Injector Nozzle Encyclopedia

1. DLLA150P1606 Injector Nozzle Technical Support   1.1.  DLLA150P1606 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA150P1606 Injector Nozzle Encyclopedia

Common Rail DLLA150P1274 Injector Nozzle Encyclopedia

1. DLLA150P1274 Injector Nozzle Technical Support   1.1.  DLLA150P1274 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA150P1274 Injector Nozzle Encyclopedia

Common Rail DLLA149P2597 Injector Nozzle Encyclopedia

1. DLLA149P2597 Injector Nozzle Technical Support   1.1.  DLLA149P2597 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA149P2597 Injector Nozzle Encyclopedia

Common Rail DLLA149P1787 Injector Nozzle Encyclopedia

1. DLLA149P1787 Injector Nozzle Technical Support   1.1.  DLLA149P1787 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA149P1787 Injector Nozzle Encyclopedia

Common Rail DLLA148P2710 Injector Nozzle Encyclopedia

1. DLLA148P2710 Injector Nozzle Technical Support   1.1.  DLLA148P2710 Injector Nozzle Installation Precautions (1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine… Read More »Common Rail DLLA148P2710 Injector Nozzle Encyclopedia

1. DLLA148P2710 Injector Nozzle Technical Support

 

1.1.  DLLA148P2710 Injector Nozzle Installation Precautions

(1) Clean the injector nozzle in an ultrasonic cleaner for 3-5 minutes before installation, so as to make the stains, dust, rust-proof oil oxides, paraffin base, naphthenic base, intermediate base, salt, lead naphthenate, zinc naphthenate, sodium petroleum sulfonate, barium petroleum sulfonate, calcium petroleum sulfonate, tallow diamine trioleate, rosinamine on the surface of the injector nozzle fall off.

 

(2) Use compressed air to clean the cleaning fluid attached to the surface of the injector nozzle after cleaning, and clean it up to the standard of use.

 

1.2. DLLA148P2710 Injector Nozzle Inspection

(1) Check whether there is deformation, cracking, thread damage, quenching, leakage and rust in the guide sleeve, spring, gasket and tight cap of the nozzle. The tight cap of the nozzle must be replaced after being disassembled for more than 5 times, as shown in the following.

 

Pic No.1

(2) Replace the tight cap of the  nozzle and the copper gasket of the injector nozzle.

(3) Check whether the gap between the nozzle needle and the nozzle shell is within the standard range and whether it reaches the standard for use.

 

1.3. DLLA148P2710 Injector Nozzle Test Measurement 

(1) Nozzle opening pressure test

Test whether the opening pressure range of the nozzle is within the range specified in the injector maintenance manual (to be verified), if not within the normal range, adjust the nozzle spring to adjust the gasket

 

(2) Stroke Measurement of Nozzle Needle Valve

Use a measuring tool to measure whether the stroke of the nozzle needle valve is within the range (15-45um) specified in the injector maintenance manual. If not, adjust the stroke of the nozzle to adjust the gasket.

 

Pic No.2

 If the value is greater than normal, thicken the gasket for oil-nozzle needle valve lift adjustment; if the value is less than normal, reduce the gasket for oil-nozzle needle valve lift adjustment.

 

1.4. DLLA148P2710 Injector Nozzle Installation

(1) Tightening torque of injector nozzle

The torque lever and tightening moment specified in the injector maintenance manual must be installed when the injector nozzle is installed. (50Nm)

Pic No.3

 The tightening torque of the nozzle cap must be installed in accordance with the tightening torque specified in the injector maintenance manual.

 

 

2. Copyright Statement 

All content on this passage DLLA148P2710 Injector Nozzle Encyclopedia” is sourced from and belongs to Shenzhen Shumatt Technology Co., Ltd. www.injectorpart.com has been authorized to use this content. Any reproduction, distribution, or public display of this material must clearly acknowledge Shenzhen Shumatt Technology Co., Ltd. as the source. Unauthorized use or failure to comply with these conditions will constitute a violation of the “Copyright Law of the People’s Republic of China” and other relevant international laws and regulations.